[OmniOS-discuss] Multipathing, only one path visible - there ought to be two, what am i doing wrong?

Nitram Grebredna nitram at konsortit.se
Fri Mar 28 15:33:17 UTC 2014


Hi guys!

Thanks for the input. I've had a second look at the backplane and you were
right Chris, it's not dual port. Should i set mpxio-disable="yes" to
disable mpxio on the sas driver or should i leave it as is? My guess would
be to disable mpxio to actually see which controller holds which disk, this
to be able to spread the mirror-sets across multiple controllers. Would you
agree?

Best regards,

Martin


On Wed, Mar 26, 2014 at 8:02 PM, Russell Hansen <russhan at new-swankton.net>wrote:

> Because those disks don't have Sun/Oracle firmware I believe you need to
> update /kernel/drv/scsi_vhci.conf
>
> scsi-vhci-failover-override =
> "SEAGATE ST3300657SS", "f_sym",
> "SEAGATE ST4000NM0023", "f_sym";
>
> You can double-check the VID/PID string by running format -> disk# ->
> inquiry
>
> -Russ
>
>
>
> From: OmniOS-discuss [omnios-discuss-bounces at lists.omniti.com] on behalf
> of Chris Ferebee [cf at ferebee.net]
>
> Sent: Wednesday, March 26, 2014 10:33 AM
>
> To: omnios-discuss at lists.omniti.com
>
> Subject: Re: [OmniOS-discuss] Multipathing, only one path visible - there
> ought to be two, what am i doing wrong?
>
>
>
>
>
>
> Martin,
>
>
>
> Are you sure you have SAS expanders in your backplane? Supermicro will
> sell you the same chassis with or without expanders, with almost identical
> model numbers.
>
>
>
> You've described a typical JBOD configuration (i. e., no expanders): Each
> LSI 2308 has 8 SAS/SATA ports, 4 ports on each of 2 Mini-SAS SFF8087
> connectors. Thus, with 3 controllers you are running 3 x 8 = 24 SAS ports
> to the backplane.
>
>
>
> Do you have the exact model number of the chassis or backplane?
>
>
>
> Best,
> Chris
>
>
> Am 26.03.2014 um 14:05 schrieb Nitram Grebredna <nitram at konsortit.se>:
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
> Hi!
>
>
>
>
> I'm having issues with multipathing, and i cant seem to figure out what is
> wrong.
>
>
>
>
>
> The setup is a Supermicro 24 disk-box with 3 controllers (1 pcs internal
> SAS2308, two 9207i-cards, same firmware on all units), identified as
> follows:
>
>
>
> Num   Ctlr            FW Ver        NVDATA        x86-BIOS         PCI Addr
>
>
> ----------------------------------------------------------------------------
>
>
>
> 0  SAS2308_2(D1)   18.00.00.00    11.00.00.05    07.33.00.00
> 00:01:00:00
>
> 1  SAS2308_2(D1)   18.00.00.00    11.00.00.05    07.33.00.00
> 00:02:00:00
>
> 2  SAS2308_2(D1)   18.00.00.00    11.00.00.05    07.33.00.00
> 00:03:00:00
>
>
>
>
> The machine has 12 ST4000NM0023 (seagate 4TB DP) disks in it and a couple
> or bootdisks. The controllers are connected via 2 cables per controller to
> the backplane/expander. I've Installed latest stable omnios on it.
>
>
>
>
> Excerpt from dmesg:
>
>
>
> [...]
>
>
>
> genunix: [ID 936769
> kern.info] mpt_sas2 is /pci at 0,0/pci8086,e06 at 2,2/pci1000,3020 at 0
>
> scsi: [ID 583861
> kern.info] mpt_sas7 at mpt_sas2: scsi-iport 4
>
> genunix: [ID 936769
> kern.info] mpt_sas7 is /pci at 0,0/pci8086,e06 at 2,2/pci1000,3020 at 0/iport at 4
>
> genunix: [ID 408114
> kern.info] /pci at 0,0/pci8086,e06 at 2,2/pci1000,3020 at 0/iport at 4 (mpt_sas7)
> online
>
> scsi: [ID 583861
> kern.info] sd11 at scsi_vhci0: unit-address g5000c50057c1fce3: conf f_sym
>
> genunix: [ID 936769
> kern.info] sd11 is /scsi_vhci/disk at g5000c50057c1fce3
>
> genunix: [ID 408114
> kern.info] /scsi_vhci/disk at g5000c50057c1fce3 (sd11) online
>
> genunix: [ID 483743
> kern.info] /scsi_vhci/disk at g5000c50057c1fce3 (sd11) multipath status:
> degraded: path 4 mpt_sas15/disk at w5000c50057c1fce1,0 is online
>
> scsi: [ID 583861
> kern.info] mpt_sas11 at mpt_sas1: scsi-iport 2
>
> genunix: [ID 936769
> kern.info] mpt_sas11 is /pci at 0,0/pci8086,e04 at 2/pci1000,3020 at 0/iport at 2
>
> genunix: [ID 408114
> kern.info] /pci at 0,0/pci8086,e04 at 2/pci1000,3020 at 0/iport at 2 (mpt_sas11)
> online
>
> scsi: [ID 583861
> kern.info] sd2 at scsi_vhci0: unit-address g5000c50057ca74bb: conf f_sym
>
> genunix: [ID 936769
> kern.info] sd2 is /scsi_vhci/disk at g5000c50057ca74bb
>
> genunix: [ID 408114
> kern.info] /scsi_vhci/disk at g5000c50057ca74bb (sd2) online
>
>
>
> [...]
>
>
>
>
> Excerpt from mpathadm:
>
>
>
> # mpathadm list lu
>
>         /dev/rdsk/c1t5000C5006C0BF63Fd0s2
>
>                 Total Path Count: 1
>
>                 Operational Path Count: 1
>
>         /dev/rdsk/c1t5000C5006C0B29C7d0s2
>
>                 Total Path Count: 1
>
>                 Operational Path Count: 1
>
>         /dev/rdsk/c1t5000C50057C1F5BFd0s2
>
>                 Total Path Count: 1
>
>
>
> [...]
>
>
>
>
>
>
> Excerpt from format:
>
>
>
> # format
>
> Searching for disks...done
>
>
>
>
>
> AVAILABLE DISK SELECTIONS:
>
>        0. c1t5000C5006C0B29C7d0 <SEAGATE-ST3300657SS-0008 cyl 36469 alt 2
> hd 255 sec 63>
>
>           /scsi_vhci/disk at g5000c5006c0b29c7
>
>        1. c1t5000C5006C0BF63Fd0 <SEAGATE-ST3300657SS-0008 cyl 36469 alt 2
> hd 255 sec 63>
>
>           /scsi_vhci/disk at g5000c5006c0bf63f
>
>        2. c1t5000C50057C1F5BFd0 <SEAGATE-ST4000NM0023-0003-3.64TB>
>
>           /scsi_vhci/disk at g5000c50057c1f5bf
>
>        3. c1t5000C50057C1FCE3d0 <SEAGATE-ST4000NM0023-0003-3.64TB>
>
>           /scsi_vhci/disk at g5000c50057c1fce3
>
>
>
> [...]
>
>
>
>
> If i set mpxio-disable="yes"; in mpt_sas.conf the error above obviously
> dissapears and also i can see the 'real' device/controller id's when
> issuing the format command.
>
>
>
>
>
> If things were working correctly i assume i would see a total path count
> of 2 per disk, and the multipath status wouldn't be set as degraded in the
> log? What am i doing wrong? I've asked google and since they dont know the
> answer to the question i'd thought
>  i'd try a post here ;)
>
>
>
>
> Thanks in advance for any help,
>
>
>
>
> Martin
>
>
>
>
>
> _______________________________________________
>
> OmniOS-discuss mailing list
>
> OmniOS-discuss at lists.omniti.com
>
> http://lists.omniti.com/mailman/listinfo/omnios-discuss
>
>
>
>
>
>
> _______________________________________________
> OmniOS-discuss mailing list
> OmniOS-discuss at lists.omniti.com
> http://lists.omniti.com/mailman/listinfo/omnios-discuss
>
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <https://omniosce.org/ml-archive/attachments/20140328/5291af4c/attachment-0001.html>


More information about the OmniOS-discuss mailing list